+86-317-4168868

Whole-Bag Testing Methods in the National Standard for Container Bags

Oct 09, 2025

The main whole-bag testing methods in the national standard for container bags are as follows:
1. Periodic Lifting Test

Fill the container bag evenly to full capacity with the contents. Apply a load twice the maximum load. Repeat this test 70 times for a limited-use bag or 30 times for a disposable bag. The container bag's compliance is determined by whether there are any abnormalities in the contents or the bag itself, or any damage to the joints. If no abnormalities are observed, the container bag passes this test.
2. Vertical Drop Test

Lift the fully loaded container bag using a lifting device, with the bottom of the bag at least 0.8 m off the ground. Then, drop it vertically onto a hard, flat surface. If the contents do not spill and the bag is intact, the container bag passes this test.

3. Pressure Test
A fully loaded bulk bag is placed on a pressurizing machine and subjected to a pressure test at a pressure of four times the bag's full weight, or using a static load method, the deadweight of four layers of fully loaded bags. The pressure is applied for at least eight hours. The bag passes this test if the contents do not overflow and the bag shows no damage.
4. Tipping Test
Stack fully loaded bulk bags three high. Secure the top bag with a rope and pull it over. Observe the bag's performance. The bag passes this test if the base fabric, seams, or other abnormalities are not observed.
5. Uprightness Test
A fully loaded bulk bag is placed on its side on the ground. Use a lifting device to hook onto one or two lifting lugs (if the bag has four lifting lugs) and hoist it to an upright position at a speed of at least 0.1 m/s, ensuring it is well off the ground. In this test, the bag passes if no abnormalities occur in the bag body or the seams between the bag body and the slings.

6. Tear Test

Stand the fully loaded bag upright on the ground. Make a 100mm long incision at a 45° angle through the main axis of the bag at any location on the lower side of the bag. Then, lift the bag off the ground, hold it for at least five minutes, and then lower it to the ground. The bag passes this test if the incision length does not extend by more than 25%.

 